Abstract
An experimental program conducted in order to analyze the behaviour of reinforced concrete columns jacketed with FRP composites and subjected to axial compression and cyclic horizontal loads is described. The dimensions of the cylindrical columns were 1500 mm height by 250mm diameter. The influence of various parameters on the response, including the type of FRP usedon confinement is reported. The results of the tests are shown and interpreted.
Original language | Unknown |
---|---|
Title of host publication | none |
Pages | 162-163 |
Publication status | Published - 1 Jan 2008 |
Event | CCC 2008 - Challenges for Civil Construction - Duration: 1 Jan 2008 → … |
Conference
Conference | CCC 2008 - Challenges for Civil Construction |
---|---|
Period | 1/01/08 → … |