Post-earthquake performance of a slab-column connection with punching shear reinforcement

Research output: Contribution to journalArticle

Abstract

Brittle punching failures can occur in slab–column connections due to earthquake-induced unbalanced moments. The performance of undamaged specimens and various repair/strengthening techniques have been studied in the past. This paper investigates a less studied scenario, in which a flat slab–column connection severely damaged by an earthquake is subjected to another earthquake without undergoing repair. The performance under this special loading protocol is analysed. It is shown that the drift capacity was not significantly impaired, but both the lateral and bending stiffness were reduced. Other relevant observations regarding the post-earthquake life of slab–column connections are brought to attention.

Original languageEnglish
JournalJournal of Earthquake Engineering
DOIs
Publication statusAccepted/In press - 2 Jan 2020

Fingerprint Dive into the research topics of 'Post-earthquake performance of a slab-column connection with punching shear reinforcement'. Together they form a unique fingerprint.