T1 - Optimising protocol of acquisition and post-processing procedures in the assessment of coronary artery disease by computed tomography
AU - Ribeiro, Maria Margarida
AU - Gonçalves, Nuno Caldeira
AU - Bate, Inês Baião
AU - O'Neill, João Goyri
AU - Maurício, Jaime Cruz
PY - 2015/4/3
Y1 - 2015/4/3
N2 - Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semi-automated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developing CAD to be predicted will be presented. A 64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.
AB - Coronary artery disease (CAD) is currently one of the most prevalent diseases in the world population and calcium deposits in coronary arteries are one direct risk factor. These can be assessed by the calcium score (CS) application, available via a computed tomography (CT) scan, which gives an accurate indication of the development of the disease. However, the ionising radiation applied to patients is high. This study aimed to optimise the protocol acquisition in order to reduce the radiation dose and explain the flow of procedures to quantify CAD. The main differences in the clinical results, when automated or semi-automated post-processing is used, will be shown, and the epidemiology, imaging, risk factors and prognosis of the disease described. The software steps and the values that allow the risk of developing CAD to be predicted will be presented. A 64-row multidetector CT scan with dual source and two phantoms (pig hearts) were used to demonstrate the advantages and disadvantages of the Agatston method. The tube energy was balanced. Two measurements were obtained in each of the three experimental protocols (64, 128, 256 mAs). Considerable changes appeared between the values of CS relating to the protocol variation. The predefined standard protocol provided the lowest dose of radiation (0.43 mGy). This study found that the variation in the radiation dose between protocols, taking into consideration the dose control systems attached to the CT equipment and image quality, was not sufficient to justify changing the default protocol provided by the manufacturer.
KW - computational bio-imaging and visualisation
KW - data processing and analysis
KW - medical clinics
KW - medical imaging and visualisation
UR - http://www.scopus.com/inward/record.url?scp=84981363469&partnerID=8YFLogxK
U2 - 10.1080/21681163.2014.895680
DO - 10.1080/21681163.2014.895680
M3 - Article
AN - SCOPUS:84981363469
SN - 2168-1163
VL - 3
SP - 91
EP - 100
JO - Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization
JF - Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization
IS - 2
ER -