T1 - Femoroacetabular Contact Force Measurement in Hip Arthroscopy
T2 - Surgical Technique
AU - Dantas, Pedro
AU - Gonçalves, Sérgio Rodrigues
AU - Gonçalves, Sérgio Rodrigues
AU - Mascarenhas, Vasco
AU - Martins, Jorge
AU - Tavares da Silva, Miguel
AU - Consciência, J. Guimarães
N1 - Funding Information:
The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: P.D. reports research funding from CUF related to this study as part of a doctoral scholarship grant; and speaking and lecture fees from Smith & Nephew and DePuy Synthes. S.B.G. reports financial support was provided by Portuguese Foundation for Science and Technology, through IDMEC, under LAETA, project UIDB/50022/2020. J.M. reports financial support was provided by Portuguese Foundation for Science and Technology, through IDMEC, under LAETA, project UIDB/50022/2020. M.T.d.S. reports financial support was provided by Portuguese Foundation for Science and Technology, through IDMEC, under LAETA, project UIDB/50022/2020. All other authors (S.r.G., V.M., J.G.C.) declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Publisher Copyright:
© 2024 The Authors
PY - 2024/9
Y1 - 2024/9
N2 - The femoroacetabular contact force and pressure are increased in the anterosuperior segment of the acetabulum in femoroacetabular impingement syndrome. We developed a special device for femoroacetabular contact force measurement in hip arthroscopy and present the surgical technique for measuring femoroacetabular contact force in the intact joint with a cam morphology and after cam resection, with the hip in different positions in a cadaver specimen. The device is introduced into the joint peripheral compartment. After joint distraction, the sensor is deployed through the cannula and advanced into the central compartment under direct arthroscopic control. We show a decrease in the contact force measured with this device after cam resection. This force analysis is limited to the anterosuperior femoroacetabular junction, which is the most frequent location for labral and chondral pathology in cam-type femoroacetabular impingement syndrome. We believe that this device also can be used in the evaluation of the contact forces in other joint conditions and in the assessment of diverse techniques of labral repair or reconstruction.
AB - The femoroacetabular contact force and pressure are increased in the anterosuperior segment of the acetabulum in femoroacetabular impingement syndrome. We developed a special device for femoroacetabular contact force measurement in hip arthroscopy and present the surgical technique for measuring femoroacetabular contact force in the intact joint with a cam morphology and after cam resection, with the hip in different positions in a cadaver specimen. The device is introduced into the joint peripheral compartment. After joint distraction, the sensor is deployed through the cannula and advanced into the central compartment under direct arthroscopic control. We show a decrease in the contact force measured with this device after cam resection. This force analysis is limited to the anterosuperior femoroacetabular junction, which is the most frequent location for labral and chondral pathology in cam-type femoroacetabular impingement syndrome. We believe that this device also can be used in the evaluation of the contact forces in other joint conditions and in the assessment of diverse techniques of labral repair or reconstruction.