Historic buildings are a living representation of our past and it is our duty to ensure that future generations have access to their heritage. In order to accomplish this, it is necessary to determine the conditions that the buildings are in and, if needs be, to make the necessary changes. In this latter stage, it is helpful to have a validated whole-building hygrothermal model since it takes into consideration most of the processes that affect their hygrothermal performance, thus allowing us to choose the most appropriate interventions. This paper aims to establish a validation process for historic buildings based on annual indoor conditions using simulation software. Hence, the indoor conditions is a 13th century church in Lisbon were monitored over a year. The model accuracy was assessed by comparing the simulated and measured temperature and water-vapour pressure, and quantified using the coefficient of determination, coefficient of variation of the root mean square error, normalized mean bias error and goodness of fit. The hygrothermal model was then validated by comparison against other models in literature and existing standards/guidelines. Four outdoor weather files were simulated to show the importance of monitoring the outdoor climate as closely as possible to the case-study. The soil/slab interface temperature was obtained using six different models. A sensitivity analysis was developed to optimize some of the inputs. Ultimately, the church hygrothermal model was validated. However, in hygrothermal models the simulation time can be long, therefore, a simplified model was developed using two of the four tested simplifications.

Original languageEnglish
Pages (from-to)439-450
Number of pages12
JournalBuilding and Environment
Volume142
DOIs
Publication statusPublished - 1 Sep 2018

Fingerprint

simulation model
building
simulation
historic building
Religious buildings
church
Vapor pressure
vapor pressure
Mean square error
Water vapor
Sensitivity analysis
sensitivity analysis
slab
water vapor
climate
monitoring
temperature
water
weather
Soils

Keywords

  • Computational model
  • Historic buildings
  • Hygrothermal simulation
  • Model calibration

Cite this

Coelho, Guilherme B.A. ; Silva, Hugo Entradas ; Henriques, Fernando M.A. / Calibrated hygrothermal simulation models for historical buildings. In: Building and Environment. 2018 ; Vol. 142. pp. 439-450.
@article{f2295e5ba571444ab9627578a825c8c3,
title = "Calibrated hygrothermal simulation models for historical buildings",
abstract = "Historic buildings are a living representation of our past and it is our duty to ensure that future generations have access to their heritage. In order to accomplish this, it is necessary to determine the conditions that the buildings are in and, if needs be, to make the necessary changes. In this latter stage, it is helpful to have a validated whole-building hygrothermal model since it takes into consideration most of the processes that affect their hygrothermal performance, thus allowing us to choose the most appropriate interventions. This paper aims to establish a validation process for historic buildings based on annual indoor conditions using simulation software. Hence, the indoor conditions is a 13th century church in Lisbon were monitored over a year. The model accuracy was assessed by comparing the simulated and measured temperature and water-vapour pressure, and quantified using the coefficient of determination, coefficient of variation of the root mean square error, normalized mean bias error and goodness of fit. The hygrothermal model was then validated by comparison against other models in literature and existing standards/guidelines. Four outdoor weather files were simulated to show the importance of monitoring the outdoor climate as closely as possible to the case-study. The soil/slab interface temperature was obtained using six different models. A sensitivity analysis was developed to optimize some of the inputs. Ultimately, the church hygrothermal model was validated. However, in hygrothermal models the simulation time can be long, therefore, a simplified model was developed using two of the four tested simplifications.",
keywords = "Computational model, Historic buildings, Hygrothermal simulation, Model calibration",
author = "Coelho, {Guilherme B.A.} and Silva, {Hugo Entradas} and Henriques, {Fernando M.A.}",
note = "sem pdf conforme despacho. Funda{\cc}{\~a}o para Ci{\^e}ncia e a Tecnologia – PhD scholarships PD/BD/127844/2016 and PD/BD/52654/2014.",
year = "2018",
month = "9",
day = "1",
doi = "10.1016/j.buildenv.2018.06.034",
language = "English",
volume = "142",
pages = "439--450",
journal = "Building and Environment",
issn = "0360-1323",
publisher = "Elsevier BV",

}

Calibrated hygrothermal simulation models for historical buildings. / Coelho, Guilherme B.A.; Silva, Hugo Entradas; Henriques, Fernando M.A.

In: Building and Environment, Vol. 142, 01.09.2018, p. 439-450.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Calibrated hygrothermal simulation models for historical buildings

AU - Coelho, Guilherme B.A.

AU - Silva, Hugo Entradas

AU - Henriques, Fernando M.A.

N1 - sem pdf conforme despacho. Fundação para Ciência e a Tecnologia – PhD scholarships PD/BD/127844/2016 and PD/BD/52654/2014.

PY - 2018/9/1

Y1 - 2018/9/1

N2 - Historic buildings are a living representation of our past and it is our duty to ensure that future generations have access to their heritage. In order to accomplish this, it is necessary to determine the conditions that the buildings are in and, if needs be, to make the necessary changes. In this latter stage, it is helpful to have a validated whole-building hygrothermal model since it takes into consideration most of the processes that affect their hygrothermal performance, thus allowing us to choose the most appropriate interventions. This paper aims to establish a validation process for historic buildings based on annual indoor conditions using simulation software. Hence, the indoor conditions is a 13th century church in Lisbon were monitored over a year. The model accuracy was assessed by comparing the simulated and measured temperature and water-vapour pressure, and quantified using the coefficient of determination, coefficient of variation of the root mean square error, normalized mean bias error and goodness of fit. The hygrothermal model was then validated by comparison against other models in literature and existing standards/guidelines. Four outdoor weather files were simulated to show the importance of monitoring the outdoor climate as closely as possible to the case-study. The soil/slab interface temperature was obtained using six different models. A sensitivity analysis was developed to optimize some of the inputs. Ultimately, the church hygrothermal model was validated. However, in hygrothermal models the simulation time can be long, therefore, a simplified model was developed using two of the four tested simplifications.

AB - Historic buildings are a living representation of our past and it is our duty to ensure that future generations have access to their heritage. In order to accomplish this, it is necessary to determine the conditions that the buildings are in and, if needs be, to make the necessary changes. In this latter stage, it is helpful to have a validated whole-building hygrothermal model since it takes into consideration most of the processes that affect their hygrothermal performance, thus allowing us to choose the most appropriate interventions. This paper aims to establish a validation process for historic buildings based on annual indoor conditions using simulation software. Hence, the indoor conditions is a 13th century church in Lisbon were monitored over a year. The model accuracy was assessed by comparing the simulated and measured temperature and water-vapour pressure, and quantified using the coefficient of determination, coefficient of variation of the root mean square error, normalized mean bias error and goodness of fit. The hygrothermal model was then validated by comparison against other models in literature and existing standards/guidelines. Four outdoor weather files were simulated to show the importance of monitoring the outdoor climate as closely as possible to the case-study. The soil/slab interface temperature was obtained using six different models. A sensitivity analysis was developed to optimize some of the inputs. Ultimately, the church hygrothermal model was validated. However, in hygrothermal models the simulation time can be long, therefore, a simplified model was developed using two of the four tested simplifications.

KW - Computational model

KW - Historic buildings

KW - Hygrothermal simulation

KW - Model calibration

UR - http://www.scopus.com/inward/record.url?scp=85049116163&partnerID=8YFLogxK

U2 - 10.1016/j.buildenv.2018.06.034

DO - 10.1016/j.buildenv.2018.06.034

M3 - Article

VL - 142

SP - 439

EP - 450

JO - Building and Environment

JF - Building and Environment

SN - 0360-1323

ER -