TY - JOUR
T1 - BAlloon expandable vs. SElf expanding transcatheter vaLve for degenerated bioprosthesIs
T2 - design and rationale of the BASELINE trial
AU - Nuis, Rutger Jan
AU - van Belle, Eric
AU - Teles, Rui
AU - Blackman, Daniel
AU - Veulemans, Verena
AU - Santos, Ignacio Amat
AU - Pilgrim, Thomas
AU - Tarantini, Giuseppe
AU - Saia, Francesco
AU - Iakovou, Ioannis
AU - Mascherbauer, Julia
AU - Vincent, Flavien
AU - Geleijnse, Marcel
AU - Sathananthan, Janarthanan
AU - Wood, David
AU - Makkar, Raj
AU - Van Mieghem, Nicolas M.
N1 - Funding Information:
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Publisher Copyright:
© 2022 The Author(s)
PY - 2023/2
Y1 - 2023/2
N2 - Background: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. Methods: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. Conclusions: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).
AB - Background: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. Methods: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. Conclusions: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).
UR - http://www.scopus.com/inward/record.url?scp=85144041466&partnerID=8YFLogxK
U2 - 10.1016/j.ahj.2022.11.013
DO - 10.1016/j.ahj.2022.11.013
M3 - Article
C2 - 36410441
AN - SCOPUS:85144041466
SN - 0002-8703
VL - 256
SP - 139
EP - 147
JO - American heart journal
JF - American heart journal
ER -