Active Power Filter with Relay Current Regulator and Common DC Link for Compensation of Harmonic Distortion in Power Grids

Maksim Maratovich Habibullin, Igor Sergeevich Pavlov, Viktor Nikolaevich Mescheryakov, Stanimir Stoyanov Valtchev

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Citations (Scopus)

Abstract

The growing number of consumers representing non-linear loads has led to an increase in the level of harmonics and poor power quality. It is not news to apply active power filtering (APF), but the drawback is the lower efficiency and complexity. The described here active power filter control system is simpler and more efficient. It is based on a relay current regulator and its converter uses the existing DC bus of the rectifier. The theoretical basis of the APF is described. A model of the proposed APF (with its suggested control system and the common DC link) is simulated in Matlab. The result of this simulation demonstrates that the level of the Total Harmonic Distortion (THD) of the input current is less than 3 %. The input current matches the phase of the input (mains) voltage: i.e. the consumption of reactive power from the grid is minimized. The simulation is confirmed by experimental study of the relay current controller. The corresponding results are provided.
Original languageEnglish
Title of host publicationIFIP Advances in Information and Communication Technology
Pages427-434
Volume423
ISBN (Electronic)978-3-642-54734-8
DOIs
Publication statusPublished - 2014
Event5th IFIP WG 5.5/SOCOLNET Doctoral Conference on Computing, Electrical and Industrial Systems (DoCEIS) - Costa da Caparica, Portugal
Duration: 7 Apr 20149 Apr 2014

Conference

Conference5th IFIP WG 5.5/SOCOLNET Doctoral Conference on Computing, Electrical and Industrial Systems (DoCEIS)
Country/TerritoryPortugal
CityCosta da Caparica
Period7/04/149/04/14

Keywords

  • Active power filter
  • DC-link
  • Non-linear load
  • Quality of electric energy
  • Relay current control
  • Total harmonic distortion

Fingerprint

Dive into the research topics of 'Active Power Filter with Relay Current Regulator and Common DC Link for Compensation of Harmonic Distortion in Power Grids'. Together they form a unique fingerprint.

Cite this